TM 11-6625-255-14/TO 32A1-13-170-1
Light Assembly MX-1292/PAQ.
7-22. Modification Work Orders
b. Test Connections and Conditions.
If a modification is performed on this equipment,
(1) No connections necessary.
after modification, the spectrum analyzer must be
calibrated.
(2) Remove the top and bottom dust covers.
c. Procedure. Follow the procedures outlined in
7-23. Physical Tests and Inspections
a. Test Equipment and Materials. Electronic
Table 7-6. Physical Tests and Inspections
Control settings
Performance
Standard
Test
Test procedure
Step
Equipment
No.
under test
Equipment
Controls may be in any position. a. Inspect case and chassis for a. No damage evident or parts
None.
1
damage, missing parts, and
missing. Painted surfaces will
condition of paint.
not show bare metal. Screw-
heads, binding posts, recep-
tacles, and other plated parts
will not be painted or polished
with abrasives.
b. Inspect all controls and mechani- b. Screws, bolts and nuts will be
tight; none missing.
cal assemblies for loose or
missing screws, bolts, and
nuts.
c. Inspect all connectors, sockets, c. No loose parts or damage. No
missing parts.
and meter for looseness dam-
age or missing parts.
Controls may be in any position. a. Rotate all panel controls through- a. Controls will rotate freely with-
None.
2
out their limits of travel.
o u t binding or excessive
looseness.
b. Inspect dial stops for damage or b. Stops will operate properly with-
out evidence of damage.
bending, and for proper opera-
tion.
c. Switches will operate properly.
c. Operate all switches.
b. Test Connections and Conditions. C o n n e c t
7-24. 225-Volt Supply Regulation
the equipment as shown in figure 7-11. Remove
a . Test Equipment and Materials.
the top and bottom covers of the TS-723(*)/U.
c. Procedure. Follow the procedures outlined in
U.
7-20