TM 11-6625-2781-14&P-2
Section I
Table 1-3. Test Equipment
Item
Minimum Specifications or Required Features
Suggested Model
Frequency Comb
Frequency markers spaced 1, 10, 100 MHz apart;
HP 8406A Comb
Generator
usable to 110 MHz
Generator
Frequency Accuracy: +0.01%
Output Amplitude: >- 60 dBm
Frequency Range: 1 kHz to 10 MHz
HP 651B Test
Output Amplitude: -30 dBm
Output Flatness: +2% from 1 kHz to 10 MHz
Output Impedance: 50 ohms
HF Signal
HP 606A/B
Output Amplitude: -20 dBm
HF Signal Generator
Output Amplitude Accuracy: +1%
Frequency Accuracy: +1%
Output Impedance: 50 ohms
VHF Signal
HP 608E/F VHF
Frequency Accuracy: +1%
Signal Generator
Output Amplitude: > -20 dBm
Output Impedance: 50 ohms
Tracking Generator
Frequency Range: 1-110 MHz
HP 8443A Tracking
Output Flatness: +0.5 dB over full band
Generator/Counter
Output Impedance: 50 ohms
Output Amplitude: at least 0 dBm
(Do not substitute.)
Accuracy: 3% of reading
Input Impedance: 10 megohms
RF Impedance Meter
HP 4815A RF Vector
Accuracy: +5%
Impedance Meter with
HP 00600A Acces. Kit
Frequency Counter
Frequency Range: 3-310 MHz
HP 5245L Frequency
Accuracy: + 0.001%
Counter with HP 5252A
Sensitivity: 100 mV rms
Plug-In
Readout Digits: 7 digits
Frequency Range: 50 kHz
HP 200 CD Audio
Output Amplitude: 2 V rms
Frequency Accuracy: +2%
Square-Wave
Frequency Range: 10 kHz
HP 211B Square-Wave
Generator
Output Amplitude: 30V peak into 600 ohms
Generator
Frequency Accuracy: +5%
Power Supply
HP 6217A Power
Output Current: 0-40 mA
Supply
Amplifier
Frequency Range: 40-60 MHz
HP 461A Amplifier
Amplifier Gain: 40 dB
1-7